Protector
Relays
|
| FEATURES
|
Accuracys
from .1% to .5% |
| Din
rail, panel or rack mount units |
| All
protector relays conform to one or more of the following: UL, CSA,
CE |
| ANSI
or specific IEEE specifications |
AC
current inputs:
1 to 10 AC amperes direct, 1P or 3P, higher than 10A: use external
transformer |
AC
voltage inputs:
100 to 480 AC volts direct, 1P or 3P, 1-34,500 AC volts with external
transformer |
DC
current inputs:
1 milliamp to 10 DC amperes direct, 1-25000 DC amperes with ext.
shunt |
DC
voltage inputs:
18 to 32 VDC, 5A resistive |
| WATT,
VAR, kW, power factor, phase angle, VA:5A/120VAC, 5A/240VAC, 5A/480VAC,
1P or 3P |
| Frequency
ranges: from 50 to 400HZ |
| Thermocouple
ranges: B,C,J,K,N,R,S,T,S (specify temp range in degrees F or C)
|
| RTD
ranges: 10 OHM copper, 100 OHM platinum, multiple inputs
|
| Thermistor
trip ranges: automatic or manual reset |
| Speed
sensing ranges: from 5 to 75VDC (specify # of teeth) |
| Paralleling
ranges: live or dead bus. 1P or 3P, 120V/60HZ |
| PROTECTOR
RELAY TYPES |
AC
voltage (over, under and over/under voltage combined) 1P or 3P
|
| AC
current (over, under and over/under current combined) 1P or 3P
|
| DC
voltage including DC millivolt trip relays |
| DC
current |
| Frequency
relays |
| Hot
spot relays (multiple input temperature or RTD relays) |
| Paralleling
relays |
| Phase
Balance |
| Phase
Angle |
| Phase
Failure/Phase sequence |
| Power
Factor |
| Reverse
power (current) relays (1P or 3P/4W) and (3P/3W) |
| Speed
sensing relays |
| Synchro-check
relays |
| Temperature
or RTD relays (single input) |
| Thermistor
relays |
| Transducer
trip relays |
| Vector
shift and rate of change of frequency (R.O.C.O.F) relays |
| Watt
relays |
| Var
relays |
| ORDERING
INFORMATION |
Select
panel mount or din rail |
| Select
type of relay |
| Select
input |
NOTE:
If input is current or voltage, please specify AC or DC input
Select auxiliary power desired or self powered |
| OPTIONS
|
Customized
calibration and special auxiliary power available upon request. |
| Please
call for special applications or options not listed above
|
|
|
Back
To Top
|
Meter
Relays
|
| FEATURES
|
Single
or double setpoint (4 alarms available for digital meter relays)
|
|
2.5"
sizes, to 4..5 sizes,1/8th din for digital
|
|
All
meter relays conform to one or more of the following: UL, CSA,
or CE
|
|
AC
current inputs: 1 to 10 AC amperes direct, above 10A, transformer
rated
|
|
AC
voltage inputs: 1 to 600 AC volts direct, above 600V, 1-34,500
AC volts with external transformer
|
|
DC
current inputs: 1 milliamp to 10 DC amperes direct, 1-25000 DC
amperes with ext. shunt
|
|
DC
voltage inputs: 1 millivolt to 600 DC volts direct
|
|
Pressure
ranges: from 0-30000 PSI, 0-150,000 PSIG
|
|
Thermocouple
ranges: B,C,J,K,N,R,S,T,S (specify temp range in degrees F or
C)
|
|
RTD
ranges: 10 OHM copper, 100 OHM platinum
|
| METER
RELAY TYPES |
Digital
meter relays
|
|
Analog
meter relays: single or double setpoints, 2.5" through 6.5"
size, round, square, edgewise or switchboard
|
|
AC
voltage and current, True RMS
|
|
DC
voltage and current
|
|
Process
inputs
|
|
Pyrometer
inputs
|
|
RTD
inputs
|
|
Strain
gauge inputs
|
| Pressure
inputs |
| Pulse
inputs |
| Resistance
inputs |
| Single
Phase 2 mre watts |
| Dual
inputs |
|
Thermocouple
inputs
|
| ORDERING
INFORMATION |
Specify
digital or analog meter relay
|
|
Specify
signal input to the meter relay
|
|
Specify
scale
|
|
Specify
number of alarms required (analog: 2 alarms max, digital: 4 alarms
max)
|
|
Specify
auxiliary power and frequency (ex: 120V/60HZ, 240V/50HZ, etc.)
|
|
For
analog meter relays, specify size of unit (ex. 2.5" face
through 6.5" face)
|
| OPTIONS
|
Customized
scaling and calibration
|
|
Glass
windows
|
|
Illumination
|
|
Thumbscrew
or knob adjustments
|
|
Special
auxiliary power available upon request
|
| NOTE
|
We
typically stock Crompton and Texmate meter relays. All others,
please allow from stock to 5 weeks, depending on individual application
|
| Please
call for special applications or options not listed above
|
|
|
Back
To Top

|