  1. Type HGF3C Ground Fault Current Transformer

    Type HGF3C Ground Fault Current Transformer

    Part Number 19RT-SD-38137 50:0.025 Amps (2000:1 Ratio) Replaces Multilin P/N HGF3 Notes: 1. Ratio 50:0.025Amp 2. Insulation Class: 0.6kV, 10kV BIL 3. Frequency: 50-60Hz 4. DC Resistance approximately 26 ohms 5. Thermoplastic case on metal bracket 6. Terminals are #10-32 brass studs with one flat washer, lockwasher, and regular nut 7.Approximate weight: 3.0 lbs. (1.4 kg) 8. UL and cUL recognized 9. Dimensions shown as inches [mm] 10. Application: Ground fault sensors to work in conjunction with GE Multilin motor management relays. Specially designed to match the ground fault input of GE Multilin motor protection relays and should be used to ensure correct performance. This CT can sense low leakage currents over the relay setting range with minimum error.
    See available options
  2. Type HGF5C Ground Fault Current Transformer

    Type HGF5C Ground Fault Current Transformer

    Part Number 125-SD-38591 50:0.025 Amps (2000:1 Ratio) Replaces Multilin P/N HGF5 Notes: 1. Ratio 50:0.025Amp 2. Insulation Class: 0.6kV, 10kV BIL 3. Frequency: 50-60Hz 4. DC Resistance approximately 30 ohms 5. Thermoplastic case 6. Terminals are #10-32 brass studs with one flat washer, lockwasher, and regular nut 7.Approximate weight: 3.0 lbs. (1.4 kg) 8. UL and cUL recognized 9. Dimensions shown as inches [mm] 10. Order mounting bracket kit 0221B00231 separately 11. Application: Ground fault sensors to work in conjunction with GE Multilin motor management relays. Specially designed to match the ground fault input of GE Multilin motor protection relays and should be used to ensure correct performance. This CT can sense low leakage currents over the relay setting range with minimum error.
    See available options
  3. Type HGF8 Ground Fault Current Transformer

    Type HGF8 Ground Fault Current Transformer

    Specially designed to match the ground fault input of GE Multilin motor protection relays and should be used to ensure correct performance. This CT can sense low leakage currents over the relay setting range with minimum error.