Like what you see? Then come explore a working relationship with Spectrum Industries, Inc! Click Here for Details
Toll Free: (800) 644-9773
           Ph: (978) 532-4400
         Fax: (978) 532-4214
meters@spectrumind.com

Your Quote:

0 item(s) - $0.00
You have no items in your shopping cart.

0

Current Transformers

20 Item(s)

  1. JKW-3 Outdoor Current Transformer - 5KV Class

    JKW-3 Outdoor Current Transformer - 5KV Class

    Designed for outdoor service; suitable for operating meters, relays, and control devices. Rated Station Class with higher burden and extra creep distance. Available in a variety of ratio as outlined in the unit selection table below, with additional designs available upon request.
    See available options
  2. Model JCK-4 Outdoor Current Transformer

    Model JCK-4 Outdoor Current Transformer

    Outdoor Current Transformer 8,700V, 5A to 800A, 50/60 Hz, 75 kV BIL
    See available options
  3. JKW-350ER Outdoor Current Transformer High Accuracy - 69KV Class

    JKW-350ER Outdoor Current Transformer High Accuracy - 69KV Class

    Designed for outdoor service; suitable for operating meters, relays, and control devices. Features two independent cores; an extended range (ER) metering
    core with 0.15% accuracy from 1% of rated current to its rating factor (within burden capability), and a second core with both a relay class rating and a
    0.15% metering accuracy rating from 5% of rated current to its rating factor.
    See available options
  4. JKW-350 Outdoor Current Transformer - 69KV Class

    JKW-350 Outdoor Current Transformer - 69KV Class

    Designed for outdoor service; suitable for operating meters, relays, and control devices. Rated Station Class with higher burden and extra creep distance. Available in a variety of ratio as outlined in the unit selection table below, with additional designs available upon request.
    See available options
  5. JKW-250ER Outdoor Current Transformer High Accuracy - 46KV Class

    JKW-250ER Outdoor Current Transformer High Accuracy - 46KV Class

    Designed for outdoor service; suitable for operating meters, relays, and control devices. Features two independent cores; an extended range (ER) metering core with 0.15% accuracy from 1% of rated current to its rating factor (within burden capability), and a second core with both a relay class rating and a 0.15% metering accuracy rating from 5% of rated current to its rating factor.
    See available options
  6. JKW-250 Outdoor Current Transformer - 46KV Class

    JKW-250 Outdoor Current Transformer - 46KV Class

    Designed for outdoor service; suitable for operating meters, relays, and control devices. Rated Station Class with higher burden and extra creep distance. Available in a variety of ratio as outlined in the unit selection table below, with additional designs available upon request.
    See available options
  7. JKW-200ER Outdoor Current Transformer High Accuracy - 36KV Class

    JKW-200ER Outdoor Current Transformer High Accuracy - 36KV Class

    Designed for outdoor service; suitable for operating meters, relays, and control devices. Features two independent cores; an extended range (ER) metering
    core with 0.15% accuracy from 1% of rated current to its rating factor (within burden capability), and a second core with both a relay class rating and a
    0.15% metering accuracy rating from 5% of rated current to its rating factor.
    See available options
  8. JKW-200 Outdoor Current Transformer - 36KV Class

    JKW-200 Outdoor Current Transformer - 36KV Class

    Designed for outdoor service; suitable for operating meters, relays, and control devices. Rated Station Class with higher burden and extra creep distance. Available in a variety of ratio as outlined in the unit selection table below, with additional designs available upon request.
    See available options
  9. JKW-150ER Outdoor Current Transformer High Accuracy - 25KV Class

    JKW-150ER Outdoor Current Transformer High Accuracy - 25KV Class

    Designed for outdoor service; suitable for operating meters, relays, and control devices. Features two independent cores; an extended range (ER) metering core with 0.15% accuracy from 1% of rated current to its rating factor (within burden capability), and a second core with both a relay class rating and a 0.15% metering accuracy rating from 5% of rated current to its rating factor.
    See available options
  10. JKW-150 Outdoor Current Transformer - 25KV Class

    JKW-150 Outdoor Current Transformer - 25KV Class

    Designed for outdoor service; suitable for operating meters, relays, and control devices. Rated Station Class with higher burden and extra creep distance. Available in a variety of ratio as outlined in the unit selection table below, with additional designs available upon request.
    See available options
  11. JKW-7 Outdoor Current Transformer - 36KV Class

    JKW-7 Outdoor Current Transformer - 36KV Class

    Designed for outdoor service; suitable for revenue metering. Rated Distribution class with a compact design for maximizing efficiency in solid-state revenue metering applications. Available in a variety of ratio as outlined in the unit selection table below, with additional designs available upon request.
    See available options
  12. JKW-3A Outdoor Current Transformer High Accuracy - 5KV Class

    JKW-3A Outdoor Current Transformer High Accuracy - 5KV Class

    Designed for outdoor service; suitable for operating meters, relays, and control devices. Features 0.15 accuracy from 5% of nameplate amps through rating factor within burden capability. Available in a variety of ratio as outlined in the unit selection table below, with additional designs available upon request. Rated Station Class with higher burden and extra creep distance.
    See available options
  13. JKW-4 Outdoor Current Transformer - 8.7KV Class

    JKW-4 Outdoor Current Transformer - 8.7KV Class

    Designed for outdoor service; suitable for operating meters, relays, and control devices. Rated Station Class with higher burden and extra creep distance. Available in a variety of ratio as outlined in the unit selection table below, with additional designs available upon request.
    See available options
  14. JKW-4A Outdoor Current Transformer High Accuracy - 8.7KV Class

    JKW-4A Outdoor Current Transformer High Accuracy - 8.7KV Class

    Designed for outdoor service; suitable for operating meters, relays, and control devices. Features 0.15 accuracy from 5% of nameplate amps through rating factor within burden capability. Available in a variety of ratio as outlined in the unit selection table below, with additional designs available upon request. Rated Station Class with higher burden and extra creep distance.
    See available options
  15. JKW-5 Outdoor Current Transformer - 15KV Class

    JKW-5 Outdoor Current Transformer - 15KV Class

    Designed for outdoor service; suitable for operating meters, relays, and control devices. Rated Station Class with higher burden and extra creep distance. Available in a variety of ratio as outlined in the unit selection table below, with additional designs available upon request
    See available options
  16. JKW-5A Outdoor Current Transformer High Accuracy - 15KV Class

    JKW-5A Outdoor Current Transformer High Accuracy - 15KV Class

    Designed for outdoor service; suitable for operating meters, relays, and control devices. Features 0.15 accuracy from 5% of nameplate amps through rating factor within burden capability. Available in a variety of ratio as outlined in the unit selection table below, with additional designs available upon request. Rated Station Class with higher burden and extra creep distance.
    See available options
  17. JKW-6 Outdoor Current Transformer - 25KV Class

    JKW-6 Outdoor Current Transformer - 25KV Class

    Designed for outdoor service; suitable for operating meters, relays, and control devices. Rated Distribution class with a compact design for maximizing efficiency in solid-state revenue metering applications. Model JKW-6 is also has designs for substation application with higher burden and relay ratings.
    See available options
  18. JKW-6A Outdoor Current Transformer High Accuracy - 25KV Class

    JKW-6A Outdoor Current Transformer High Accuracy - 25KV Class

    Designed for outdoor service; suitable for operating meters, relays, and control devices. Features 0.15 accuracy from 5% of nameplate amps through rating factor within burden capability. Available in a variety of ratio as outlined in the unit selection table below, with additional designs available upon request.
    See available options
  19. Model JCK-3 Outdoor Current Transformer

    Model JCK-3 Outdoor Current Transformer

    Outdoor Current Transformer, 1,200 A to 4,000 A, 5.56" Window, 50/60 Hz 5,000 V to 15,000 V, BIL 60 kV to 110 kV
    See available options
  20. Model JCK-5 Outdoor Current Transformer

    Model JCK-5 Outdoor Current Transformer

    Outdoor Current Transformer 15,000V, 5A to 800A, 50/60 Hz, 110kV BIL
    See available options

20 Item(s)

© Spectrum Industries. All Rights Reserved.