Transducers
& Signal Conditioners
Measure, isolate and convert various inputs into industry
standard output signals
|
Transducers
|
TRANSDUCER
FEATURES |
Multiple
outputs
|
|
Accuracys
from .1% to .5%
|
|
Din
rail, panel or rack mount units
|
|
All
transducers conform to one or more of the following: UL, CSA,
CE
|
| ANSI
or specific IEEE specifications |
|
AC
current inputs: 1 to 600 AC amperes direct, 1P or 3P
|
|
AC
voltage inputs: 1 to 600 AC volts direct, 1-34,500 AC volts with
external transformer, 1P or 3P
|
|
DC
voltage inputs: 1 milliamp to 10 DC amperes direct, 1-25000 DC
amperes with External shunt
|
|
DC
current inputs: 1 millivolt to 600 DC volts direct
|
|
Watt,
var, kW, power factor, phase angle, VA: 5A/120VAC, 5A/240VAC,
5A/480 VAC, 1P or 3P
|
|
Frequency
ranges: from 10HZ to 440HZ
|
TRANSDUCER
TYPES |
Current
transducers (average and true RMS) 1P or 3P
|
|
Frequency
transducers
|
|
Multiple
outputs and user selectable transducers (Hsiang Cheng)
|
|
Panel
mount utility grade (.2% accuracy or better)
|
|
Phase
angle transducers
|
|
Power
factor transducers
|
|
Pressure
transducers
|
|
Pulse
output transducers
|
|
VA
transducers
|
|
VAR
transducers
|
|
VAR
hour transducers
|
|
VAR/VAR
hour transducers
|
|
Voltage
transducers (average and true RMS) 1P or 3P
|
|
Watt
transducers
|
|
Watt
hour transducers
|
|
Watt/Watt-hour
transducers
|
|
Watt/Var
transducers (combination)
|
ORDERING
INFORMATION |
Specify
panel mount or din rail
|
|
Specify
.2% accuracy (utility grade) or .5% accuracy (industrial grade)
|
|
Specify
single or 3 phase (specify 2 wire, 3 wire or 4 wire)
|
|
Select
input
|
|
NOTE:
If input is current or voltage, please specify AC or DC input.
If input is watts, vars power factor, etc., please specify CT
ratio PT ratio and scale for calibration purposes
|
|
Select
output
|
|
EX:
0-1MADC, 4-20MADC, 0-10VDC, 1-5 VDC, RS232 or RS485 communications,
etc.
|
TRANSDUCER
OPTIONS |
RS232
or RS485 output
|
|
Optical
communications output
|
|
DC
auxiliary power
|
|
Self
powered
|
|
Special
inputs, outputs, accuracys and calibration
|
|
Custom
designs
|
| Please
call for special applications or options not listed above |
|
|
Back To Top
|
Signal
Conditioners, Transmitters and Isolators
|
| FEATURES
|
Multiple
outputs
|
|
Accuracys
from .1% to .5%
|
|
Din
rail, panel or rack mount units
|
|
Conforms
to one or more of the following: UL, CSA, CE, ANSI or Specific
IEEE specifications
|
|
DC
current inputs: 1 millivolt to 10 DC amperes direct, 1-25000 DC
amperes with ext. shunt
|
|
DC
voltage inputs: 1 milliamp to 600DC volts direct
|
|
Pressure
ranges: from 0-30000 PSI, 0-150,000 PSIG
|
|
Pulse
ranges from 100 to 10,000 pulses/hour
|
|
Thermocouple
ranges: B,C,J,K,N,R,S,T,S (specify temp range in degrees F or
C)
|
|
RTD
ranges: 10 OHM copper, 100 OHM platinum
|
|
Slide
wire ranges (potentiometric): from 1K to 50K OHMS
|
|
Tap
position ranges: from 10-50 taps at 30 OHMS, 5-50 TAPS at 400
OHMS
|
| TYPES
|
DC
to DC transducers, transmitters
|
|
Loop
powered isolators
|
|
Potentiometer
isolators
|
|
Pressure
transmitters (GP50)
|
|
Resistance
transmitters (Crompton)
|
|
RTD
signal conditioners
|
|
Slide
wire transmitters (Crompton)
|
|
Strain
gauge transmitters (Crompton)
|
|
Tap
position transmitters (Crompton)
|
|
Thermocouple
signal conditioners
|
| ORDERING
INFORMATION |
Specify
panel mount or din rail
|
|
Select
input
|
|
NOTE;
If input is current or voltage, please specify AC or DC input.
Select output.
Select auxiliary power desired or self powered.
|
| OPTIONS
|
Alarm
relays
|
|
LCD
display
|
|
Custom
calibration
|
|
|
Back To Top

|